HeartStart FRx

For those who get there first

For those who get there first

With a Rugged and reliable construction the HeartStart FRx AED makes it perfect for the first responder

Rugged design - Ready for real-world use

The HeartStart FRx was built to surpass rigorous testing requirements: withstanding jetting water, crushing loads of up to 500 pounds, and a one-meter drop onto concrete.

On-demand CPR coaching

Talks you through your training

The HeartStart FRx features CPR coaching and intuitive icon-driven operation. Calm, clear voice instructions are tailored to the responder’s actions, providing guidance during the resuscitation of an SCA victim.

Lightweight

At just 3.5 pounds, the HeartStart FRx is light and portable, allowing for easy transport. Its size and weight make it perfect for police officers, firefighters, and trained public servants.

Built-in self test

Ready when needed

Your HeartStart FRx goes through a 120-point test before it leaves the factory. On the job, it conducts self tests every single day, not just weekly. It performs over 80 different tests in all. Even the pads are tested for readiness.

SMART Biphasic therapy

Safely delivers maximum shock strength

Philips SMART Biphasic therapy uses a unique combination of high current - to increase effectiveness, and a lower energy dose - to decrease side effects that are harmful to a fragile heart.

Quick Shock

Minimize chest compression interruptions

CPR is even more vital to survival than previously realized. Rapidly delivering a shock after chest compressions is critical. The HeartStart FRx’s Quick Shock feature reduces the time between hands-off and shock delivery.

Ready-Pack

Ready to rescue, out of the box

The HeartStart FRx Ready-Pack configuration arrives virtually ready-to-rescue. The device is pre-installed in the carry case and the battery and pads are pre-installed in the device. You have peace of mind that it is deployed correctly.

Specifications

Model Number 861304

How the Defibrillator is supplied: Battery (one, pre-installed), SMART Pads II (one set, pre-installed), Set up / Maintenance guide with expiration date tags, Owner's Manual, Quick Reference Guide.

Waveform Truncated Exponential Biphasic. Waveform parameters adjusted as a function of each patient’s impedance.

Therapy Adult defibrillation peak current: 32A (150J nominal) into a 50 ohm load. Pediatric defibrillation (with optional Infant/Child Key installed): 19A (50J nominal) into a 50 ohm load.

Protocol Protocol Device follows preconfigured settings. Defibrillation and CPR protocol can be customized using HeartStart Event Review or HeartStart Configure software.

User Interface

Instructions Detailed voice prompts and visual icons guide responder through use of the defibrillator

CPR Coaching Voice coaching for adult and infant/child CPR provides instructions and audio cues for the appropriate number, rate and depth of chest compressions, as well as for each breath.

Controls Green On/Off button, blue i-button, orange Shock button, optional Infant/Child key.

Indicators Ready light, blue i-button, caution light, illuminated pads, icons, Shock button lights up when shock is advised.

Physical requirements

Size 2.4 x 7.1 x 8.9 inches (6 x 18 x 22 cm) H x D x W

Weight With battery and pads case: 3.5 lbs (1.5 kg)

Without battery or pads case: 2.6 lbs (1.2 kg)

Environmental

Sealing Waterjet proof IPX5 per IEC60529

Dust protected IPX5 per IEC60529

Temperature Operating/Standby:32° - 122° F (0° - 50° C)

Altitude 0 to 15,000 feet

Aircraft Device:RTCA/DO-160D;1997

Crush 500 pounds

Vibration Operating:meets MILSTD 810F Fig.514.5C-17,random;

Standby:meets MILSTD 810F Fig.514.5C-18,swept sine.

EMI (Radiated/Immunity) CISPR II Group I Class B, IEC 61000-4-3, and IEC 61000-4-8

Patient Analysis

Patient Analysis Evaluates patient ECG to determine if a rhythm is shockable. Rhythms considered shockable are ventricular fibrillation (VF), and certain ventricular tachy-cardias (VT) associated with lack of circulation. For safety reasons, some VT rhythms associated with circulation will not be interpreted as shockable, and some very low-amplitude or low-frequency rhythms will not be interpreted as shockable VF.

Sensitivity / Specificity Meets AAMI DF80 guidelines and AHA recommendations for adult defibrillation (Circulation 1997;95:1677-1682).

Shock Advised Able to deliver a shock as soon as the device indicates a shock is advised.

Quick Shock Able to deliver a shock after the end of a CPR interval, typically in eight seconds.

Shock-to-Shock Cycle Time Typically less than 20 seconds between shocks in a series.

Artifact Detection Advanced signal processing allows accurate ECG analysis even in the presence of most pacemaker artifact and electrical noise sources. Other artifacts are detected and corrective voice prompts issued.

Battery Back to top 

Item Number (s) Standard:M5070A

Type 9 Volt DC, 4.2 Ah,lithium manganese dioxide, disposable long-life primary cell.

Capacity Minimum 200 shocks or 4 hours of operating time (EN 60601-2-4:2003).

Install-by Date Battery is labeled with an install-by date of at least five years from date of manufacture.

Standby Life Four years typical when battery is installed by the install by date.(Will power the AED in standby state within the specified standby temperature range, assuming one battery insertion test and no uses.

SMART PADS II

Item Number 989803139261

How Supplied Disposable pads case containing adhesive multifunction defibrillator pads.HeartStart plug style connector clicks into device for preconnected pads solution.

Active Surface Area 12.4 in² (80 cm²) each

Cable Length 48 inches (121.9 cm)

Use-by Date Pads case is labeled with a use-by date of at least two years from date of manufacture.

Infant/Child Key

Item Number 989803139311

Training Pads II

Item Number 989803139271

Function Special pads place HeartStart FRx into training mode and disable its energy delivery capability. Features 8 real-world training scenarios.

Automated and User-activated Self-tests

Daily Automatic

Self-tests Tests internal circuitry,waveform delivery system,pads and battery capacity.

Pads Integrity Test Specifically tests readiness-for-use of pads (gel moisture).

Battery Insertion Test Upon battery insertion, extensive automatic self-tests and user-interactive test check device readiness.

Status Indicator Blinking green "Ready" light indicates ready for use.

Data Recording and Transmission

Infrared Wireless transmission of event data to a PC or Palm® PDA, using the IrDA protocol..

HeartStart Event Review Software Data management software (optional) for download and review of data retrieved through defibrillator’s infrared data port.

Data Stored Stores first 15 minutes of ECG and the entire incident’s events and analysis decisions.