HjemDownloadsNedlastinger for LLEAP - Laerdal Learning Application

Nedlastinger for LLEAP - Laerdal Learning Application



DFU

SimStart User Guide

3.4 MB - English
10.01.2020

Simulated AED or Monitor Defibrillator training functionality available in Laerdal Learning Application- LLEAP
Quick Guide WiFi setup

1.2 MB - English
24.06.2019

Session Viewer - User Guide

2.7 MB - Multilingual
10.07.2015

Dokumenter

Laerdal Network Document rev U

0.7 MB
06.11.2024

This document describes the requirements for setting up a network on pre-existing infrastructure specifically for Laerdal simulation equipment.
LLEAP License Agreement

0.2 MB
19.09.2023

Programvare

Laerdal Learning Application (LLEAP) v. 8.7.0

1 520.0 MB
14.10.2024

Changes in this release: 

Compatibility notes:

  • This version is not compatible with Windows 7 based SimMan 3Gs. These simulators will have a serial number of 21x-13220000 or lower, and should stay on LLEAP version 8.6.1. Windows 10 based SimMan 3Gs are supported. A hardware upgrade kit to upgrade Windows 7 based simulators to Windows 10 will be made available.
  • This version of LLEAP Instructor Application is recommended when operating simulators on version 9.0.4 and higher.
    • Simulators with external LinkBox PLUS.
    • SimMom.
    • SimMan ALS.
    • SimNewB.
    • SimBaby.
    • Nursing Anne Simulator.

Bug fixes:

  • Fix for an issue where laryngospasm could not be easily deactivated.
  • Fix for an issue where it was not possible to configure new SPO2 finger for SimMan 3G.
Laerdal Patient Monitor v. 8.7.0

1 036.6 MB
14.10.2024

The Laerdal Patient Monitor software is compatible with LLEAP and SimPad.

Laerdal Patient Monitor software is included when you download LLEAP. This download allows you to install Laerdal Patient Monitor software without installing LLEAP on the same computer.

Laerdal Learning Application (LLEAP) v.8.6.1

1 347.6 MB
04.06.2024

Changes in this release: 

LLEAP

  • Compatibility notes:
    • This version of LLEAP Instructor Application is recommended when operating simulators on version 9.0.0 and higher.
      • Simulators with external LinkBox PLUS.
      • SimMom.
      • SimMan ALS.
      • SimNewB.
      • SimBaby.
      • Nursing Anne Simulator.
    • This version is not applicable to SimMan 3G simulators, no upgrade required. The version is fully compatible with SimMan 3G simulators on version 8.5.0.
      • SimMan 3G.
      • SimMan 3G PLUS.
      • SimMan Essential.
      • SimMan Ess. Bleeding.
      • SimMan 3G Trauma.
    • Improvements:
      • Added volume visibility column in VCA for better user experience.
      • Corrections for Chinese translations.
      • Improved consistency in the naming of ECG rhythms.
      • Changing the label for a gas name will not change the in-/et- values for the gas.
    • Bug fixes:
      • Fix for an issue where LLEAP Instructor Application could not reconnect to an ongoing session in some cases.
      • Correction for an issue introduced in version 8.6.0 where Physiological Patient Cases could not be run.
      • Fix for an issue where it was not possible to connect to a simulator after it had been discovered on Bluetooth.
      • Fix for Simulator crashing in relation to use of Bluetooth.
      • Fix for LLEAP not able to reconnect to simulator.
      • Fix for multimedia PDF files.
      • Fix for EFM variable not saved in theme.
      • Fix for two translation errors in the French language version of the Defibrillator Monitor.
      • Fix for an issue where data collection exception messages would be shown when connecting LLEAP Instructor Application with a SimMan 3G simulator of version 8.5.0 or older. Upgrading LLEAP Instructor Application even if simulator remains on an older version will resolve this issue.
  • Patient Monitor.
    • Improvements:
      • Automatic blood pressure measurements is done every minute by default, instead of every 2 minutes.
      • Pacing is set to On fix instead of On Demand by default.
      • Adjustments of mA can now be done in increments of 20, instead of choosing from list of predefined values.
    • Bug fixes:
      • Fix for “Set oxygen rate”.
      • Fix for User Defined Variable on number with decimal.
Laerdal Patient Monitor v. 8.6.1

864.1 MB
04.06.2024

Changes in this release:

  • Bug fixes:
    • Automatic blood pressure measurements is done every minute by default, instead of every 2 minutes.
    • Pacing is set to On fix instead of On Demand by default.
    • Adjustments of mA can now be done in increments of 20, instead of choosing from list of predefined values.
Laerdal Patient Monitor v. 7.3.0

932.6 MB
19.07.2023

The Laerdal Patient Monitor software is compatible with LLEAP and SimPad.

Laerdal Patient Monitor software is included when you download LLEAP. This download allows you to install Laerdal Patient Monitor software without installing LLEAP on the same computer.

 

Changes in this release:

  • New version to align with LLEAP 7.3.0
  • General maintenance, bugfixes and improvements.

 

Note:

Updating to Windows 10?
  • Using SimLink or Custom ad hoc network on SimPad, and considering upgrading to Windows 10 on your computers for Laerdal Patient Monitor?
    • Microsoft ended their support for this type of network with the release of Windows 8. From Windows 10 the equipment will need to use a separate simulation network.
Windows 7
  • Laerdal Patient Monitor 7.3 will be the last version that supports Windows 7
LLEAP Patch for 7.3.0

0.4 MB - English
28.07.2021

LLEAP Patch for 7.3.0, for older SimMan 3G who can't use LLEAP 8.0

 

This update is supplied to fix an issue where chest rise and lung sounds ceases on the SimMan 3G when used with ASL 5000 using a ventilator setting of PEEP 2 cm H2O or greater. The issue can also be resolved by upgrading to LLEAP 8.0.0. This patch should only be used if upgrade to 8.0.0 is not possible, e.g if using older SimMan 3G with XP embedded which is not supported on LLEAP 8.0.0 and onwards.

Important: ASL 5000 plugin needs to be uninstalled before patch installation and reinstalled afterwards. Remember to back up custom lung models when prompted during uninstall process and import again during install process after upgrade to patch.

Note:

    SimMan 3G updater might need several tries before the patch is installed on simulator
Laerdal Learning Application (LLEAP) v. 7.3.0

1 526.9 MB
16.03.2021

Changes in this release:

  • New Device Connection Manager (DCM) application to manage network configurations more efficiently on multiple manikins.
  • Enhanced support for Enterprise Network Security from SFNW & for SimMan3G with Wifi USB adapter.
  • Fixed an issue where SimMan3G system time was not synced.
  • Improved simulator connection on networks with high latency.
  • Included WiFi driver to LLEAP installer (for SOM on SimMan3G).
  • Fixed an issue where the simulation wouldn't use the wanted simulation profile unless explicitly selected. Could lead to using wrong units and similar problems.
  • LLEAP supports transport layer security (TLS) 1.2 or greater for login to Scenario Cloud.
  • Fixed an issue causing help files not to work.

 

Note:

Updating to Windows 10?
  • Using SimLink or Custom ad hoc network on SimPad, and considering upgrading to Windows 10 on your computers for Laerdal Patient Monitor?
    • Microsoft ended their support for this type of network with the release of Windows 8. From Windows 10 on, the equipment will need to use a separate simulation network. Laerdal can help you connect all your simulation equipment to a dedicated network. Learn more and get started at Laerdal.com/Network.

Last LLEAP version supporting Windows 7
  • LLEAP 7.3 will be the last version that supports Windows 7.

Last version supporting old SimMan 3G family simulators

Due to end of life for Windows XP Embedded used on older SimMan3G simulators, LLEAP will no longer supported as of this version, this applies to the following simulators - unless they have been upgraded to use Windows 7:

  • SimMan3G simulators with serial numbers lower than 212-16140000
  • SimMan3G Essential simulators with serial numbers lower than 213-16140000
  • SimMan3G Essential Bleeding simulators with serial numbers lower than 214-1614000

Windows Update
  • Before installing LLEAP, to secure a successful installation, please make sure the PC is fully updated through Windows Update. If you have problems starting LLEAP after installation, please download and run Visual C++ 2015 redistributable from this location: Microsoft Visual C++ 2015 Redistributable Update 3. . Select and run vc_redist.x86 then try running LLEAP.
SimView Downloads


24.11.2017

Use this link to download latest software to SimView
SimView Mobile Downloads


24.11.2017

Use this link to download latest software to SimView Mobile
Session Viewer Downloads


09.11.2017

Use this link to download latest software to Session Viewer


© 2001-2024 Laerdal Medical AS - Alle rettigheter reservert.